{"id":2812,"date":"2026-10-10T03:00:54","date_gmt":"2026-10-10T03:00:54","guid":{"rendered":"https:\/\/mdlinsulation.com\/?post_type=product&#038;p=2812"},"modified":"2026-10-10T03:06:27","modified_gmt":"2026-10-10T03:06:27","slug":"reinforced-ceramic-fiber-tape","status":"publish","type":"product","link":"https:\/\/mdlinsulation.com\/pt\/product\/reinforced-ceramic-fiber-tape\/","title":{"rendered":"Reinforced Ceramic Fiber Tape"},"content":{"rendered":"<div class=\"info_title\"><\/div>\n<div class=\"text_box\">\n<div class=\"txt editor-content auto-adjust-img\">\n<h2><strong>Reinforced Ceramic Fiber Tape Supplier for High-Temperature Insulation<\/strong><\/h2>\n<p>Mindelun supplies reinforced ceramic fiber tape for industrial thermal insulation, heat shielding, and high-temperature sealing applications. Made from woven aluminosilicate ceramic fiber yarn with suitable reinforcement, this flexible insulation tape offers thermal protection and improved handling strength for demanding industrial environments.<\/p>\n<p>Available in glass fiber or metal wire reinforced designs, reinforced ceramic fiber tape is suitable for selected pipe wrapping, furnace sealing, exhaust systems, and gasket applications. Custom widths, thicknesses, and roll lengths are available for industrial distributors, contractors, and equipment manufacturers.<\/p>\n<h2>Key Features of Reinforced Ceramic Fiber Tape<\/h2>\n<ul>\n<li><strong>Isolamento t\u00e9rmico:<\/strong> Helps reduce heat transfer in suitable operating conditions.<\/li>\n<li><strong>Enhanced Handling Strength:<\/strong> Reinforcement improves handling and dimensional stability during installation.<\/li>\n<li><strong>Flexible Woven Structure:<\/strong> Suitable for wrapping pipes, ducts, and selected irregular surfaces.<\/li>\n<li><strong>Op\u00e7\u00f5es de refor\u00e7o:<\/strong> Glass fiber or metal wire, depending on the product grade.<\/li>\n<li><strong>Custom Specifications:<\/strong> Different widths, thicknesses, and roll lengths for industrial applications.<\/li>\n<\/ul>\n<h2>Reinforced Ceramic Fiber Tape Specifications<\/h2>\n<div class=\"table-box\">\n<table width=\"552\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"173\" \/>\n<col width=\"139\" \/>\n<col width=\"222\" \/>\n<col width=\"202\" \/><\/colgroup>\n<tbody>\n<tr class=\"firstRow\">\n<td class=\"et2\" align=\"center\" valign=\"middle\" width=\"130\" height=\"13\">Artigo<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\" width=\"104\">Unidade<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\" width=\"166\">Resultado do teste<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\" width=\"152\">Resultado do teste<\/td>\n<\/tr>\n<tr>\n<td class=\"et2\" align=\"center\" valign=\"middle\" height=\"13\">Cor<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">\/<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">Branco<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">Branco<\/td>\n<\/tr>\n<tr>\n<td class=\"et2\" align=\"center\" valign=\"middle\" height=\"14\">Temperatura nominal<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(\u2103)<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">1260(Stainless steel fiber)<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">1000(Glass fiber)<\/td>\n<\/tr>\n<tr>\n<td class=\"et2\" align=\"center\" valign=\"middle\" height=\"14\">Using Temp<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(\u2103)<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">1000<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">650<\/td>\n<\/tr>\n<tr>\n<td class=\"et2\" align=\"center\" valign=\"middle\" height=\"13\">Di\u00e2metro da fibra<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(um)<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">44200<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">44200<\/td>\n<\/tr>\n<tr>\n<td class=\"et2\" align=\"center\" valign=\"middle\" height=\"13\">Shot content<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(%)<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">\u22648.5<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">\u22648.5<\/td>\n<\/tr>\n<tr>\n<td class=\"et3\" rowspan=\"2\" align=\"center\" valign=\"middle\" width=\"130\" height=\"27\">Thermal conductivity of average temperature<\/td>\n<td class=\"et4\" align=\"center\" valign=\"middle\">(W\/m\u00b7K)<\/td>\n<td class=\"et5\" align=\"center\" valign=\"middle\">0.13-0.19(538\u2103,8pcf\uff09<\/td>\n<td class=\"et5\" align=\"center\" valign=\"middle\">0.13-0.19(538\u2103,8pcf\uff09<\/td>\n<\/tr>\n<tr>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(%)<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">0.075-0.085(1232\u2103*24h\uff09<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">0.075-0.085(1232\u2103*24h\uff09<\/td>\n<\/tr>\n<tr>\n<td class=\"et2\" align=\"center\" valign=\"middle\" height=\"13\">Al2O\u2083<\/td>\n<td class=\"et6\" align=\"center\" valign=\"middle\">(%)<\/td>\n<td class=\"et6\" align=\"center\" valign=\"middle\">\u226745-46<\/td>\n<td class=\"et6\" align=\"center\" valign=\"middle\">\u226745-46<\/td>\n<\/tr>\n<tr>\n<td class=\"et2\" align=\"center\" valign=\"middle\" height=\"15\">SiO\u2082<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(%)<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">51-52<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">51-52<\/td>\n<\/tr>\n<tr>\n<td class=\"et3\" align=\"center\" valign=\"middle\" width=\"130\" height=\"15\">Fe\u2082O\u2083<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(%)<\/td>\n<td class=\"et6\" align=\"center\" valign=\"middle\">\uff1c0.43<\/td>\n<td class=\"et6\" align=\"center\" valign=\"middle\">\uff1c0.43<\/td>\n<\/tr>\n<tr>\n<td class=\"et3\" align=\"center\" valign=\"middle\" width=\"130\" height=\"15\">Na\u2082O + K\u2082O<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(%)<\/td>\n<td class=\"et6\" align=\"center\" valign=\"middle\">0.7-1.2<\/td>\n<td class=\"et6\" align=\"center\" valign=\"middle\">0.7-1.2<\/td>\n<\/tr>\n<tr>\n<td class=\"et3\" align=\"center\" valign=\"middle\" width=\"130\" height=\"13\">Espessura<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(mm)<\/td>\n<td class=\"et7\" colspan=\"2\" align=\"center\" valign=\"middle\" width=\"318\">2\/3\/4\/5<\/td>\n<\/tr>\n<tr>\n<td class=\"et3\" align=\"center\" valign=\"middle\" width=\"130\" height=\"13\">Largura<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(mm)<\/td>\n<td class=\"et7\" colspan=\"2\" align=\"center\" valign=\"middle\" width=\"318\">25\/50\/75\/100<\/td>\n<\/tr>\n<tr>\n<td class=\"et3\" align=\"center\" valign=\"middle\" width=\"130\" height=\"13\">Comprimento<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(mm)<\/td>\n<td class=\"et7\" colspan=\"2\" align=\"center\" valign=\"middle\" width=\"318\">20000\/30000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Contact Mindelun for available sizes, reinforcement details, and technical data sheets.<\/p>\n<h2>Applications of Reinforced Ceramic Fiber Tape<\/h2>\n<ul>\n<li><strong>Pipe and Duct Insulation:<\/strong> Flexible thermal wrapping for suitable hot pipes, ducts, and exhaust components. Explore our <a href=\"https:\/\/mdlinsulation.com\/pt\/produto\/ceramic-thermal-insulation-blanket\/\">manta de fibra cer\u00e2mica<\/a> for thicker insulation requirements.<\/li>\n<li><strong>Furnace Sealing:<\/strong> Insulation around suitable furnace openings and joints. Learn more about our <a href=\"https:\/\/mdlinsulation.com\/pt\/isolamento-de-fornos-industriais\/\">solu\u00e7\u00f5es de isolamento para fornos industriais<\/a>.<\/li>\n<li><strong>Gaskets and Expansion Joints:<\/strong> Thermal sealing in compatible high-temperature equipment. Our <a href=\"https:\/\/mdlinsulation.com\/pt\/produto\/ceramic-fiber-rope\/\">ceramic fiber rope<\/a> may also suit selected gap-filling applications.<\/li>\n<li><strong>Equipment Heat Protection:<\/strong> Thermal protection for selected industrial components. For rigid insulation applications, explore our <a href=\"https:\/\/mdlinsulation.com\/pt\/produto\/placa-de-fibra-ceramica\/\">placa de fibra cer\u00e2mica<\/a>.<\/li>\n<\/ul>\n<h2>Types of Reinforced Ceramic Fiber Tape<\/h2>\n<ul>\n<li><strong>Glass Fiber Reinforced Ceramic Fiber Tape:<\/strong> Suitable for applications within the temperature limits of the selected glass fiber reinforcement.<\/li>\n<li><strong>Wire Reinforced Ceramic Fiber Tape:<\/strong> Uses appropriate metal wire to improve handling strength and dimensional stability.<\/li>\n<li><strong>Drop Warp Ceramic Fiber Tape:<\/strong> A special woven construction for selected bolted sealing and gasket applications, subject to product availability.<\/li>\n<\/ul>\n<p>The appropriate type depends on working temperature, reinforcement compatibility, installation method, and mechanical requirements.<\/p>\n<h2>Reinforced Ceramic Fiber Tape Supplier \u2014 Mindelun<\/h2>\n<p>Mindelun supplies ceramic fiber insulation materials to distributors, industrial contractors, and equipment manufacturers. We support customized specifications and bulk orders for industrial insulation and sealing projects.<\/p>\n<p><strong>Request a Quote:<\/strong> Send us your required tape width, thickness, roll length, operating temperature, reinforcement type, and order quantity to receive product details and a quotation.<\/p>\n<h2>Perguntas Frequentes<\/h2>\n<h3>What is reinforced ceramic fiber tape used for?<\/h3>\n<p>It is used for selected high-temperature insulation, pipe wrapping, furnace sealing, heat shielding, and gasket applications.<\/p>\n<h3>What is the difference between glass fiber and wire reinforced ceramic fiber tape?<\/h3>\n<p>Glass fiber and metal wire reinforcement provide different mechanical properties and temperature limitations. The appropriate option depends on the working temperature, installation method, and required strength.<\/p>\n<h3>What temperature can reinforced ceramic fiber tape withstand?<\/h3>\n<p>The operating temperature depends on the ceramic fiber grade, reinforcement material, and service conditions. Confirm the continuous operating temperature and short-term exposure requirements before ordering.<\/p>\n<h3>Pode <a href=\"https:\/\/mdlinsulation.com\/pt\/contact-us\/\">reinforced ceramic fiber tape be customized<\/a>?<\/h3>\n<p>Yes. Width, thickness, roll length, and reinforcement options can be discussed according to available product specifications and order quantities.<\/p>\n<h3>How can I order <a href=\"https:\/\/www.mindelunmaterials.com\/contact.html\">reinforced ceramic fiber tape<\/a> in bulk?<\/h3>\n<p>Provide your required dimensions, operating temperature, reinforcement preference, application, and estimated order quantity to request a suitable specification and quotation.<\/p>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p><b>Descri\u00e7\u00e3o do produto:<\/b><\/p>\n<div class=\"txt\">\n<p><strong>N\u00edvel de temperatura:\u00a0<\/strong>1000\u00b0C,1260\u00b0C<\/p>\n<p><strong>Densidade:\u00a0<\/strong>500 kg\/m<sup>\u2083<\/sup>, 550 kg\/m<sup>\u2083\u00a0<\/sup><\/p>\n<p><strong>Especifica\u00e7\u00f5es:<\/strong><\/p>\n<p>\u2022\u00a02\u00a0x25\/50\/75\/100\u00a0x 30000mm<\/p>\n<p>\u2022\u00a03&#215;25\/50\/75\/100\u00a0x 30000mm<\/p>\n<p>\u2022\u00a04&#215;25\/50\/75\/100\u00a0x 30000mm<\/p>\n<p>\u2022\u00a05&#215;25\/50\/75\/100\u00a0x 20000mm<\/p>\n<p>S\u00e3o aceites especifica\u00e7\u00f5es personalizadas.<\/p>\n<\/div>","protected":false},"featured_media":1427,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[29],"product_tag":[262,264,263,375],"class_list":["post-2812","product","type-product","status-publish","has-post-thumbnail","product_cat-ceramic-fiber-insulation","product_tag-ceramic-fiber-tape-supplier","product_tag-ceramic-fibre-tape","product_tag-ceramic-tapes","product_tag-reinforced-ceramic-fiber-tape-supplier","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/mdlinsulation.com\/pt\/wp-json\/wp\/v2\/product\/2812","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mdlinsulation.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/mdlinsulation.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/mdlinsulation.com\/pt\/wp-json\/wp\/v2\/comments?post=2812"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mdlinsulation.com\/pt\/wp-json\/wp\/v2\/media\/1427"}],"wp:attachment":[{"href":"https:\/\/mdlinsulation.com\/pt\/wp-json\/wp\/v2\/media?parent=2812"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/mdlinsulation.com\/pt\/wp-json\/wp\/v2\/product_brand?post=2812"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/mdlinsulation.com\/pt\/wp-json\/wp\/v2\/product_cat?post=2812"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/mdlinsulation.com\/pt\/wp-json\/wp\/v2\/product_tag?post=2812"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}