{"id":2816,"date":"2026-10-10T06:20:41","date_gmt":"2026-10-10T06:20:41","guid":{"rendered":"https:\/\/mdlinsulation.com\/?post_type=product&#038;p=2816"},"modified":"2026-11-16T06:42:15","modified_gmt":"2026-11-16T06:42:15","slug":"woven-ceramic-fiber-cloth-for-industrial-heat-protection","status":"publish","type":"product","link":"https:\/\/mdlinsulation.com\/de\/product\/woven-ceramic-fiber-cloth-for-industrial-heat-protection\/","title":{"rendered":"Gewebtes Keramikfasergewebe f\u00fcr den industriellen Hitzeschutz"},"content":{"rendered":"<div class=\"info_title\"><span style=\"font-size: 1.7em; font-weight: bold;\">Gewebtes Keramikfasergewebe f\u00fcr den industriellen Hitzeschutz<\/span><\/div>\n<div class=\"text_box\">\n<div class=\"txt editor-content auto-adjust-img\">\n<p>Mindelun bietet <strong>ceramic fiber cloth<\/strong> for industrial heat insulation, thermal shielding, and refractory textile applications. Manufactured from woven ceramic fiber yarn, this flexible fabric is designed for applications where conformability, thermal resistance, and practical fabrication are important.<\/p>\n<p>Depending on the selected construction, <strong>high-temperature ceramic fiber cloth<\/strong> may incorporate glass fiber filament or metal wire reinforcement to improve handling strength and fabric integrity. It can be fabricated into pipe insulation wraps, furnace curtains, removable insulation covers, expansion joint fabrics, and selected sealing components. Custom dimensions and bulk supply options are available subject to product specifications.<\/p>\n<h2>Benefits of Ceramic Fiber Cloth<\/h2>\n<ul>\n<li><strong>Flexible woven fabric:<\/strong> Suitable for wrapping equipment and fabricating insulation components.<\/li>\n<li><strong>Thermal protection:<\/strong> Helps reduce heat transfer in suitable industrial applications.<\/li>\n<li><strong>Reinforced construction options:<\/strong> Reinforcement can be selected according to available grades and service requirements.<\/li>\n<li><strong>Fabrication versatility:<\/strong> Can be cut and formed into selected covers, curtains, and protective assemblies.<\/li>\n<li><strong>Multiple industrial applications:<\/strong> Suitable for thermal insulation, heat shielding, and selected sealing systems.<\/li>\n<li><strong>Procurement flexibility:<\/strong> Product dimensions and packaging can be discussed for industrial orders.<\/li>\n<\/ul>\n<h2>Ceramic Fiber Cloth Product Specifications<\/h2>\n<div class=\"table-box\">\n<table width=\"552\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col width=\"173\" \/>\n<col width=\"139\" \/>\n<col width=\"222\" \/>\n<col width=\"202\" \/><\/colgroup>\n<tbody>\n<tr class=\"firstRow\">\n<td class=\"et2\" align=\"center\" valign=\"middle\" width=\"130\" height=\"13\">Artikel<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\" width=\"104\">Einheit<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\" width=\"166\">Testergebnis<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\" width=\"152\">Testergebnis<\/td>\n<\/tr>\n<tr>\n<td class=\"et2\" align=\"center\" valign=\"middle\" height=\"13\">Farbe<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">\/<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">Wei\u00df<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">Wei\u00df<\/td>\n<\/tr>\n<tr>\n<td class=\"et2\" align=\"center\" valign=\"middle\" height=\"14\">Spezifikationstemperatur<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(\u2103)<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">1260(Stainless steel fiber)<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">1000(Glass fiber)<\/td>\n<\/tr>\n<tr>\n<td class=\"et2\" align=\"center\" valign=\"middle\" height=\"14\">Using Temp<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(\u2103)<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">1000<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">650<\/td>\n<\/tr>\n<tr>\n<td class=\"et2\" align=\"center\" valign=\"middle\" height=\"13\">Faserdurchmesser<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(um)<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">44200<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">44200<\/td>\n<\/tr>\n<tr>\n<td class=\"et2\" align=\"center\" valign=\"middle\" height=\"13\">Shot content<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(%)<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">\u22648.5<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">\u22648.5<\/td>\n<\/tr>\n<tr>\n<td class=\"et3\" rowspan=\"2\" align=\"center\" valign=\"middle\" width=\"130\" height=\"27\">Thermal conductivity of average temperature<\/td>\n<td class=\"et4\" align=\"center\" valign=\"middle\">(W\/m\u00b7K)<\/td>\n<td class=\"et5\" align=\"center\" valign=\"middle\">0.13-0.19(538\u2103,8pcf\uff09<\/td>\n<td class=\"et5\" align=\"center\" valign=\"middle\">0.13-0.19(538\u2103,8pcf\uff09<\/td>\n<\/tr>\n<tr>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(%)<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">0.075-0.085(1232\u2103*24h\uff09<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">0.075-0.085(1232\u2103*24h\uff09<\/td>\n<\/tr>\n<tr>\n<td class=\"et2\" align=\"center\" valign=\"middle\" height=\"13\">Al\u2082O\u2083<\/td>\n<td class=\"et6\" align=\"center\" valign=\"middle\">(%)<\/td>\n<td class=\"et6\" align=\"center\" valign=\"middle\">\u226745-46<\/td>\n<td class=\"et6\" align=\"center\" valign=\"middle\">\u226745-46<\/td>\n<\/tr>\n<tr>\n<td class=\"et2\" align=\"center\" valign=\"middle\" height=\"15\">SiO\u2082<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(%)<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">51-52<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">51-52<\/td>\n<\/tr>\n<tr>\n<td class=\"et3\" align=\"center\" valign=\"middle\" width=\"130\" height=\"15\">Fe\u2082O\u2083<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(%)<\/td>\n<td class=\"et6\" align=\"center\" valign=\"middle\">\uff1c0.43<\/td>\n<td class=\"et6\" align=\"center\" valign=\"middle\">\uff1c0.43<\/td>\n<\/tr>\n<tr>\n<td class=\"et3\" align=\"center\" valign=\"middle\" width=\"130\" height=\"15\">Na\u2082O + K\u2082O<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(%)<\/td>\n<td class=\"et6\" align=\"center\" valign=\"middle\">0.7-1.2<\/td>\n<td class=\"et6\" align=\"center\" valign=\"middle\">0.7-1.2<\/td>\n<\/tr>\n<tr>\n<td class=\"et3\" align=\"center\" valign=\"middle\" width=\"130\" height=\"13\">Dicke<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(mm)<\/td>\n<td class=\"et7\" colspan=\"2\" align=\"center\" valign=\"middle\" width=\"318\">2\/3\/4\/5<\/td>\n<\/tr>\n<tr>\n<td class=\"et3\" align=\"center\" valign=\"middle\" width=\"130\" height=\"13\">Breite<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(mm)<\/td>\n<td class=\"et7\" colspan=\"2\" align=\"center\" valign=\"middle\" width=\"318\">1000<\/td>\n<\/tr>\n<tr>\n<td class=\"et3\" align=\"center\" valign=\"middle\" width=\"130\" height=\"13\">L\u00e4nge<\/td>\n<td class=\"et2\" align=\"center\" valign=\"middle\">(mm)<\/td>\n<td class=\"et7\" colspan=\"2\" align=\"center\" valign=\"middle\" width=\"318\">20000\/30000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em>For accurate selection, please confirm the actual product dimensions, reinforcement type, temperature rating, and technical data sheet with our sales team.<\/em><\/p>\n<h2>Available Ceramic Fiber Cloth Constructions<\/h2>\n<h3>Glass Fiber Reinforced Ceramic Fiber Cloth<\/h3>\n<p>This construction combines ceramic fiber yarn with glass fiber reinforcement. It can be considered for suitable flexible insulation covers, pipe wrapping, and industrial heat protection applications. The allowable temperature of the glass fiber reinforcement must be considered when selecting the complete fabric.<\/p>\n<h3>Metal Wire Reinforced Ceramic Fiber Cloth<\/h3>\n<p>Metal wire reinforced ceramic fiber cloth incorporates wire into the woven structure to improve mechanical integrity under suitable operating conditions. Depending on the wire material and fabric design, it may be suitable for furnace curtains, expansion joint fabrics, and other industrial thermal protection assemblies.<\/p>\n<p>The reinforcement type should be selected according to the required mechanical strength, operating temperature, and environmental conditions.<\/p>\n<h2>Industrial Applications of Ceramic Fiber Cloth<\/h2>\n<h3>Pipe and Equipment Insulation<\/h3>\n<p>Ceramic fiber cloth can be incorporated into selected insulation systems for pipes, exhaust lines, and industrial equipment. Its woven structure allows fabrication into flexible wraps and protective layers where the overall insulation design permits.<\/p>\n<h3>Furnace Curtains and Thermal Shields<\/h3>\n<p>Suitable ceramic fiber cloth grades can be fabricated into curtains and shields for selected industrial heating environments. The correct material depends on heat exposure, mechanical stress, and the required protection performance.<\/p>\n<h3>Expansion Joints and Flexible Insulation Systems<\/h3>\n<p>Reinforced ceramic fiber cloth may be used in suitable expansion joint assemblies and removable insulation covers. Fabric construction, reinforcement, and installation design should match the movement and service conditions of the equipment.<\/p>\n<h3>Gaskets and High-Temperature Sealing<\/h3>\n<p>Ceramic fiber cloth can be incorporated into selected gasket and sealing products where flexible refractory textile materials are required. Suitability depends on compression requirements, temperature, chemical exposure, and the complete sealing design.<\/p>\n<p>Explore our related <a href=\"https:\/\/mdlinsulation.com\/de\/isolierung-von-industrieofen\/\">Isolierung von Industrie\u00f6fen<\/a> solutions and <a href=\"https:\/\/mdlinsulation.com\/de\/product\/warmedammmatte-aus-keramik\/\">Keramikfasermatte<\/a> Produkte.<\/p>\n<h2>How to Choose a Ceramic Fiber Cloth Supplier<\/h2>\n<p>When sourcing <strong>ceramic fiber cloth for industrial applications<\/strong>, buyers should confirm the following requirements:<\/p>\n<ul>\n<li><strong>Operating conditions:<\/strong> Specify continuous temperature, intermittent exposure, and possible contact with flames or hot particles.<\/li>\n<li><strong>Fabric construction:<\/strong> Confirm whether the application requires glass fiber or metal wire reinforcement.<\/li>\n<li><strong>Dimensions:<\/strong> Provide the required thickness, width, and roll length.<\/li>\n<li><strong>End use:<\/strong> Identify whether the cloth is intended for wrapping, curtains, expansion joints, covers, or sealing components.<\/li>\n<li><strong>Order requirements:<\/strong> Confirm quantity, packaging, delivery schedule, and required technical documentation.<\/li>\n<\/ul>\n<h2>Ceramic Fiber Cloth Supply from Mindelun<\/h2>\n<p>Mindelun supplies industrial thermal insulation materials for distributors, contractors, equipment manufacturers, and other B2B buyers. We help customers evaluate product options according to application conditions and required specifications.<\/p>\n<p>Contact Mindelun for <strong>ceramic fiber cloth bulk orders<\/strong>, technical information, and quotations. Please include your application, operating temperature, dimensions, preferred reinforcement, and estimated order quantity so our team can confirm the appropriate product options.<\/p>\n<h2>H\u00e4ufig gestellte Fragen<\/h2>\n<h3>What is woven ceramic fiber cloth?<\/h3>\n<p>Woven ceramic fiber cloth is a flexible refractory textile made from ceramic fiber yarns. It is used in selected thermal insulation, heat shielding, and industrial fabrication applications.<\/p>\n<h3>What are the main applications of <a href=\"https:\/\/www.mindelunmaterials.com\/contact.html\">ceramic fiber cloth<\/a>?<\/h3>\n<p>Common applications include pipe wrapping, furnace curtains, thermal shields, removable insulation covers, expansion joints, and selected high-temperature sealing assemblies.<\/p>\n<h3>Should I choose glass fiber or metal wire reinforced ceramic fiber cloth?<\/h3>\n<p>The choice depends on the reinforcement&#8217;s temperature limitations, required mechanical integrity, and service conditions. Confirm the available product construction and technical data before ordering.<\/p>\n<h3>Is ceramic fiber cloth suitable for continuous high-temperature service?<\/h3>\n<p>Suitability depends on the ceramic fiber grade, reinforcement material, and operating environment. The temperature rating of the complete fabric may differ from the classification temperature of its base fiber.<\/p>\n<h3>Kann <a href=\"https:\/\/mdlinsulation.com\/de\/kontaktieren-sie-uns\/\">Mindelun<\/a> supply ceramic fiber cloth in customized dimensions?<\/h3>\n<p>Available dimensions and reinforcement options depend on the product range. Contact our team with your required thickness, width, roll length, application, and order quantity for confirmation.<\/p>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p><b>Produktbeschreibung:<\/b><\/p>\n<div class=\"txt\">\n<p><strong>Zeitarbeitsstufe:\u00a0<\/strong>1000\u00b0C,1260\u00b0C<\/p>\n<p><strong>Dichte:\u00a0<\/strong>500 kg\/m<sup>\u2083<\/sup>, 550 kg\/m<sup>\u2083\u00a0<\/sup><\/p>\n<p><strong>Spezifikation:<\/strong><\/p>\n<p>\u2022\u00a02\u00a0x1000 x 30000mm<\/p>\n<p>\u2022\u00a03&#215;1000 x 30000mm<\/p>\n<p>\u2022\u00a04&#215;1000 x 30000mm<\/p>\n<p>\u2022\u00a05&#215;1000 x 20000mm<\/p>\n<p>Individuelle Spezifikationen sind m\u00f6glich.<\/p>\n<\/div>","protected":false},"featured_media":194,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[29],"product_tag":[271,269,270,272],"class_list":["post-2816","product","type-product","status-publish","has-post-thumbnail","product_cat-ceramic-fiber-insulation","product_tag-ceramic-cloth","product_tag-ceramic-fiber-cloth-factory","product_tag-ceramic-fiber-weaved-cloth","product_tag-insulation-cloth","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/mdlinsulation.com\/de\/wp-json\/wp\/v2\/product\/2816","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mdlinsulation.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/mdlinsulation.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/mdlinsulation.com\/de\/wp-json\/wp\/v2\/comments?post=2816"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mdlinsulation.com\/de\/wp-json\/wp\/v2\/media\/194"}],"wp:attachment":[{"href":"https:\/\/mdlinsulation.com\/de\/wp-json\/wp\/v2\/media?parent=2816"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/mdlinsulation.com\/de\/wp-json\/wp\/v2\/product_brand?post=2816"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/mdlinsulation.com\/de\/wp-json\/wp\/v2\/product_cat?post=2816"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/mdlinsulation.com\/de\/wp-json\/wp\/v2\/product_tag?post=2816"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}