{"id":1486,"date":"2026-09-07T06:48:54","date_gmt":"2026-09-07T06:48:54","guid":{"rendered":"https:\/\/mdlinsulation.com\/?post_type=product&#038;p=1486"},"modified":"2026-11-19T06:44:54","modified_gmt":"2026-11-19T06:44:54","slug":"ceramic-fiber-fire-barrier-board","status":"publish","type":"product","link":"https:\/\/mdlinsulation.com\/de\/product\/ceramic-fiber-fire-barrier-board\/","title":{"rendered":"Brandschutzplatte aus Keramikfaser"},"content":{"rendered":"<h1>Brandschutzplatte aus Keramikfaser<\/h1>\n<h2>High Temperature Thermal Protection for Industrial Equipment<\/h2>\n<p>Mindelun Ceramic Fiber Fire Barrier Board is a rigid insulation material designed for thermal separation, heat shielding, and high-temperature equipment protection.<\/p>\n<p>Made primarily from alumina-silicate ceramic fibers, this board combines a lightweight structure with low thermal conductivity and good thermal stability. Its rigid form makes it suitable for applications where flexible insulation materials are difficult to install or maintain in a fixed position.<\/p>\n<p>Unlike ceramic fiber blankets used for wrapping irregular surfaces, ceramic fiber fire barrier boards provide a flat, stable structure for thermal partitions, furnace door panels, equipment shields, and customized insulation barriers.<\/p>\n<p>Mindelun offers 1260\u00b0C and 1400\u00b0C classification temperature grades to meet different industrial thermal protection requirements.<\/p>\n<h2>Why Use Ceramic Fiber Board for Thermal Barriers?<\/h2>\n<p>In industrial equipment, heat can transfer through exposed surfaces, partitions, furnace doors, and equipment compartments. Properly selected insulation barriers help control heat transfer and protect surrounding components.<\/p>\n<p>Ceramic fiber fire barrier boards offer several practical advantages:<\/p>\n<ul>\n<li><strong>Thermal Separation:<\/strong> Helps reduce heat transfer between high-temperature areas and adjacent equipment.<\/li>\n<li><strong>Geringe W\u00e4rmeleitf\u00e4higkeit:<\/strong> Reduces heat transmission through insulated structures.<\/li>\n<li><strong>Rigid Panel Structure:<\/strong> Maintains a fixed shape for partition and panel applications.<\/li>\n<li><strong>Lightweight Construction:<\/strong> Helps reduce the additional load on equipment structures.<\/li>\n<li><strong>Easy Fabrication:<\/strong> Can be cut, drilled, and machined into panels or customized components.<\/li>\n<li><strong>Flexible Installation:<\/strong> Suitable for flat surfaces, equipment enclosures, furnace doors, and thermal protection assemblies.<\/li>\n<li><strong>Multiple Temperature Grades:<\/strong> Available in 1260\u00b0C and 1400\u00b0C classification temperature options.<\/li>\n<\/ul>\n<h2>Typical Applications of Ceramic Fiber Fire Barrier Board<\/h2>\n<h3>1. Industrial Equipment Heat Shields<\/h3>\n<p>Ceramic fiber boards can be fabricated into heat shields and protective panels around industrial heating equipment, burners, and other heat sources.<\/p>\n<p>They help reduce heat transfer to adjacent components and provide an additional insulation layer in equipment protection systems.<\/p>\n<h3>2. Furnace Doors and Thermal Partitions<\/h3>\n<p>Rigid ceramic fiber boards are suitable for furnace door insulation, internal partitions, and thermal separation panels.<\/p>\n<p>Their flat structure makes them easier to cut and fit into specific equipment dimensions.<\/p>\n<h3>3. Industrial Kiln Thermal Barriers<\/h3>\n<p>In ceramic, glass, and other high-temperature processing industries, ceramic fiber boards can be used in kiln doors, internal partitions, and selected furnace lining structures.<\/p>\n<p>For larger furnace lining projects, they can be combined with flexible ceramic fiber blanket insulation.<\/p>\n<p>Related product: <a href=\"https:\/\/mdlinsulation.com\/de\/product\/warmedammmatte-aus-keramik\/\">Ceramic Fiber Blanket for Industrial Furnace Insulation<\/a><\/p>\n<h3>4. Burner and Heating Equipment Protection<\/h3>\n<p>Ceramic fiber boards can be processed into burner surrounds, protective covers, and insulation panels according to equipment drawings.<\/p>\n<p>The appropriate material grade and thickness should be selected based on actual operating temperatures and exposure conditions.<\/p>\n<h3>5. Industrial Thermal Separation Panels<\/h3>\n<p>For equipment requiring separation between hot and relatively cooler sections, rigid ceramic fiber panels can serve as part of a thermal barrier assembly.<\/p>\n<p>The supporting structure, fixing method, joints, and insulation thickness should be considered together to achieve the required thermal performance.<\/p>\n<h2>Ceramic Fiber Fire Barrier Board Specifications<\/h2>\n<p>Mindelun provides two main classification temperature series for different thermal protection requirements.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Technical Parameters<\/th>\n<th>1260\u00b0C Series<\/th>\n<th>1400\u00b0C Series<\/th>\n<\/tr>\n<tr>\n<td>Note<\/td>\n<td>Standard \/ High Purity<\/td>\n<td>High Alumina \/ Zirconia<\/td>\n<\/tr>\n<tr>\n<td>Klassifizierungstemperatur<\/td>\n<td>1260 \u00b0C<\/td>\n<td>1400\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Dichte<\/td>\n<td>300\u2013400 kg\/m\u00b3<\/td>\n<td>300\u2013400 kg\/m\u00b3<\/td>\n<\/tr>\n<tr>\n<td>Permanent Linear Change<\/td>\n<td>\u2264 -3%<\/td>\n<td>\u2264 -3%<\/td>\n<\/tr>\n<tr>\n<td>Test Condition<\/td>\n<td>1100\u00b0C \u00d7 24h<\/td>\n<td>1200\u00b0C \u00d7 24h<\/td>\n<\/tr>\n<tr>\n<td>Thermal Conductivity at 200\u00b0C<\/td>\n<td>0.103 W\/(m\u00b7K)<\/td>\n<td>0.103 W\/(m\u00b7K)<\/td>\n<\/tr>\n<tr>\n<td>Thermal Conductivity at 400\u00b0C<\/td>\n<td>0.125 W\/(m\u00b7K)<\/td>\n<td>0.125 W\/(m\u00b7K)<\/td>\n<\/tr>\n<tr>\n<td>Thermal Conductivity at 600\u00b0C<\/td>\n<td>0.151 W\/(m\u00b7K)<\/td>\n<td>0.151 W\/(m\u00b7K)<\/td>\n<\/tr>\n<tr>\n<td>Moisture Content<\/td>\n<td>\u2264 1%<\/td>\n<td>\u2264 1%<\/td>\n<\/tr>\n<tr>\n<td>Organic Content<\/td>\n<td>\u2264 5%<\/td>\n<td>\u2264 5%<\/td>\n<\/tr>\n<tr>\n<td>Standard Size<\/td>\n<td>900 \u00d7 600 mm<\/td>\n<td>900 \u00d7 600 mm<\/td>\n<\/tr>\n<tr>\n<td>Dicke<\/td>\n<td>10\u201350 mm<\/td>\n<td>10\u201350 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Important Technical Information:<\/strong><\/p>\n<ul>\n<li>Classification temperature is not the recommended continuous operating temperature.<\/li>\n<li>Permanent linear change is measured under the specified temperature and holding time.<\/li>\n<li>Thermal conductivity values are average test results at the corresponding mean temperatures.<\/li>\n<li>Actual performance depends on the operating environment, installation method, thermal cycling, and exposure conditions.<\/li>\n<li>Customized dimensions and specifications can be discussed according to project requirements.<\/li>\n<\/ul>\n<p>For detailed technical specifications and product grade information, see our <a href=\"https:\/\/mdlinsulation.com\/de\/product\/keramikfaserplatte\/\">Ceramic Fiber Insulation Board<\/a> range.<\/p>\n<h2>How to Select the Right Fire Barrier Board?<\/h2>\n<p>Choosing a suitable ceramic fiber thermal barrier requires more than checking its classification temperature.<\/p>\n<p>Consider the following factors before purchasing:<\/p>\n<p><strong>1. Betriebstemperatur<\/strong><\/p>\n<p>Identify the actual operating temperature and the temperature of the board&#8217;s hot face. Do not select a product solely according to its classification temperature.<\/p>\n<p><strong>2. Required Insulation Thickness<\/strong><\/p>\n<p>The thickness affects heat transfer, installation space, and the overall thermal performance of the barrier. The appropriate thickness should be determined according to the required temperature difference and equipment design.<\/p>\n<p><strong>3. Density and Mechanical Requirements<\/strong><\/p>\n<p>Density influences the board&#8217;s weight and mechanical properties. Consider whether the board needs to support its own weight, withstand handling, or be fixed within an equipment structure.<\/p>\n<p><strong>4. Installation and Fixing Method<\/strong><\/p>\n<p>Consider the supporting frame, fixing points, joints, and possible thermal expansion. Proper installation helps prevent gaps and damage during operation.<\/p>\n<p><strong>5. Thermal Cycling and Exposure Conditions<\/strong><\/p>\n<p>Repeated heating and cooling, direct flame exposure, gas flow, and mechanical vibration may affect service life. Select the appropriate grade and construction according to actual working conditions.<\/p>\n<h2>Ceramic Fiber Fire Barrier Board vs. Ceramic Fiber Blanket<\/h2>\n<p>Both products are used for high-temperature insulation, but their structures and installation methods are different.<\/p>\n<table>\n<tbody>\n<tr>\n<th>Vergleich<\/th>\n<th>Keramikfaserplatte<\/th>\n<th>Keramikfasermatte<\/th>\n<\/tr>\n<tr>\n<td>Structure<\/td>\n<td>Rigid<\/td>\n<td>Flexibel<\/td>\n<\/tr>\n<tr>\n<td>Main Form<\/td>\n<td>Flat Panels<\/td>\n<td>Rolls<\/td>\n<\/tr>\n<tr>\n<td>Installation<\/td>\n<td>Panels and partitions<\/td>\n<td>Wrapping and lining<\/td>\n<\/tr>\n<tr>\n<td>Machining<\/td>\n<td>Schneiden und Bohren<\/td>\n<td>Cutting and shaping<\/td>\n<\/tr>\n<tr>\n<td>Typical Uses<\/td>\n<td>Heat shields, furnace doors, partitions<\/td>\n<td>Furnace linings, pipes, irregular surfaces<\/td>\n<\/tr>\n<tr>\n<td>Hauptvorteil<\/td>\n<td>Stable shape<\/td>\n<td>Flexible installation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>For rigid thermal barriers and equipment panels, ceramic fiber boards are generally more convenient. For large curved surfaces and pipe insulation, ceramic fiber blankets are usually more suitable.<\/p>\n<p>Related product: <a href=\"https:\/\/mdlinsulation.com\/de\/product\/warmedammmatte-aus-keramik\/\">Keramikfasermatte<\/a><\/p>\n<h2>Custom Ceramic Fiber Fire Barrier Components<\/h2>\n<p>Not all thermal protection applications use standard rectangular boards.<\/p>\n<p>For equipment manufacturers and industrial projects, ceramic fiber boards can be processed into customized components, including:<\/p>\n<ul>\n<li>Burner insulation panels<\/li>\n<li>Furnace door insulation inserts<\/li>\n<li>Heat shield plates<\/li>\n<li>Thermal separation panels<\/li>\n<li>Equipment covers<\/li>\n<li>Customized insulation blocks<\/li>\n<\/ul>\n<p>Mindelun can manufacture customized shapes according to customer drawings, samples, dimensions, and application requirements.<\/p>\n<p>For more complex shapes, explore our <a href=\"https:\/\/mdlinsulation.com\/de\/product\/ceramic-fiber-special-shaped-products\/\">Ceramic Fiber Special Shaped Products<\/a>.<\/p>\n<h2>Related High Temperature Insulation Materials<\/h2>\n<p>Different parts of industrial equipment may require different insulation structures.<\/p>\n<p>Mindelun provides a range of complementary materials:<\/p>\n<ul>\n<li><a href=\"https:\/\/mdlinsulation.com\/de\/product\/warmedammmatte-aus-keramik\/\">Keramikfasermatte<\/a> \u2013 Flexible insulation for furnace linings and irregular surfaces.<\/li>\n<li><a href=\"https:\/\/mdlinsulation.com\/de\/product\/ceramic-fiber-paper\/\">Keramikfaserpapier<\/a> \u2013 Thin insulation and high-temperature sealing applications.<\/li>\n<li><a href=\"https:\/\/mdlinsulation.com\/de\/product\/keramikfasermodul\/\">Keramikfasermodule<\/a> \u2013 Modular lining systems for industrial furnaces.<\/li>\n<li><a href=\"https:\/\/mdlinsulation.com\/de\/product\/keramikfaserplatte\/\">Keramikfaserplatte<\/a> \u2013 Rigid insulation panels for industrial applications.<\/li>\n<li><a href=\"https:\/\/mdlinsulation.com\/de\/isolierung-von-industrieofen\/\">Isolierung von Industrie\u00f6fen<\/a> \u2013 Integrated insulation materials for furnace projects.<\/li>\n<\/ul>\n<h2>H\u00e4ufig gestellte Fragen<\/h2>\n<h3>1. What is a ceramic fiber fire barrier board used for?<\/h3>\n<p>It is used for thermal separation, heat shielding, furnace door insulation, equipment protection, and other high-temperature insulation applications.<\/p>\n<h3>2. Is ceramic fiber board suitable for fire barriers?<\/h3>\n<p>Ceramic fiber board can be used as a high-temperature thermal barrier in suitable industrial assemblies. However, its use does not automatically establish a certified fire-resistance rating for a building wall, door, or complete fire protection system. Relevant assembly testing is required where certified ratings are needed.<\/p>\n<h3>3. What is the difference between a fire barrier board and a regular ceramic fiber board?<\/h3>\n<p>The terms often describe the same basic rigid ceramic fiber material. Fire barrier board emphasizes its use in thermal protection and separation applications, while ceramic fiber board is the broader product category.<\/p>\n<h3>4. Can ceramic fiber fire barrier boards withstand direct flame exposure?<\/h3>\n<p>The suitability for direct flame exposure depends on the product grade, temperature, gas flow, mechanical conditions, and installation design. Direct flame applications should be evaluated individually rather than assumed suitable for every board.<\/p>\n<h3>5. What temperature grades are available?<\/h3>\n<p>Mindelun offers 1260\u00b0C and 1400\u00b0C classification temperature series, including Standard, High Purity, High Alumina, and Zirconia grades.<\/p>\n<h3>6. What thickness is available?<\/h3>\n<p>Standard thicknesses range from 10 mm to 50 mm. Customized thicknesses and dimensions can be discussed according to project requirements.<\/p>\n<h3>7. Can ceramic fiber boards be cut into special shapes?<\/h3>\n<p>Yes. Ceramic fiber boards can be cut, drilled, milled, and fabricated into customized insulation components according to drawings or samples.<\/p>\n<h3>8. How can I choose the right ceramic fiber fire barrier board?<\/h3>\n<p>Please provide the operating temperature, required thickness, installation dimensions, exposure conditions, and application. These details help determine the appropriate grade and insulation construction.<\/p>\n<h2>Request a Ceramic Fiber Fire Barrier Board Solution<\/h2>\n<p>Looking for a suitable thermal protection material for your industrial equipment?<\/p>\n<p>Send Mindelun your application details, equipment drawings, required dimensions, and operating temperature. Our team can help evaluate the suitable ceramic fiber board grade and customized processing requirements.<\/p>\n<p><strong><a href=\"https:\/\/www.mindelunmaterials.com\/contact.html\">Kontaktieren Sie Mindelun<\/a> for product information, samples, and a quotation.<\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p><b>Produktbeschreibung:<\/b><\/p>\n<div class=\"txt\">\n<p><strong>Zeitarbeitsstufe: <\/strong>1260\u00b0C,1400\u00b0C<\/p>\n<p><strong>Dichte:\u00a0<\/strong>300kg\/m<sup>\u2083<\/sup>, 350kg\/m<sup>\u2083<\/sup><\/p>\n<p><strong>Spezifikation:<\/strong><\/p>\n<p>\u2022 13 x600\/1200 x 900\/1200mm<\/p>\n<p>\u2022\u00a025&#215;600\/1200 x 900\/1200mm<\/p>\n<p>\u2022\u00a038&#215;600\/1200 x 900\/1200mm<\/p>\n<p>\u2022\u00a050&#215;600\/1200 x 900\/1200mm<\/p>\n<p>Individuelle Spezifikationen sind m\u00f6glich.<\/p>\n<\/div>","protected":false},"featured_media":1405,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_monsterinsights_skip_tracking":false,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[29],"product_tag":[205,204,207,206],"class_list":["post-1486","product","type-product","status-publish","has-post-thumbnail","product_cat-ceramic-fiber-insulation","product_tag-ceramic-fiber-fire-barrier-board-supplier","product_tag-ceramic-fiber-fire-barrier-boards","product_tag-fireproof-ceramic-board","product_tag-insulation-ceramic-fiber-board","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/mdlinsulation.com\/de\/wp-json\/wp\/v2\/product\/1486","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mdlinsulation.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/mdlinsulation.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/mdlinsulation.com\/de\/wp-json\/wp\/v2\/comments?post=1486"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mdlinsulation.com\/de\/wp-json\/wp\/v2\/media\/1405"}],"wp:attachment":[{"href":"https:\/\/mdlinsulation.com\/de\/wp-json\/wp\/v2\/media?parent=1486"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/mdlinsulation.com\/de\/wp-json\/wp\/v2\/product_brand?post=1486"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/mdlinsulation.com\/de\/wp-json\/wp\/v2\/product_cat?post=1486"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/mdlinsulation.com\/de\/wp-json\/wp\/v2\/product_tag?post=1486"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}